近地面大氣電場(chǎng)數(shù)據(jù)EMD方法分析
DOI:
作者:
作者單位:

作者簡(jiǎn)介:

通訊作者:

中圖分類號(hào):

基金項(xiàng)目:

公益性行業(yè)科研專項(xiàng)(GYHY200806014)和江蘇省研究生培養(yǎng)創(chuàng)新工程(CXLX11_0624)共同資助


EMD Based Analysis of Atmospheric Electric Field Data
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪問(wèn)統(tǒng)計(jì)
  • |
  • 參考文獻(xiàn)
  • |
  • 相似文獻(xiàn)
  • |
  • 引證文獻(xiàn)
  • |
  • 資源附件
  • |
  • 文章評(píng)論
    摘要:

    將經(jīng)驗(yàn)?zāi)B(tài)分解(EMD)方法應(yīng)用于2009年夏季近地面大氣電場(chǎng)資料的分析,分解出雷暴和晴天天氣大氣電場(chǎng)的不同時(shí)間尺度變化分量,并提取兩類天氣狀態(tài)下的大氣電場(chǎng)振蕩特征進(jìn)行對(duì)比。結(jié)果表明:EMD方法適合應(yīng)用于近地面大氣電場(chǎng)資料的分析,雷暴天氣大氣電場(chǎng)以晴天天氣大氣電場(chǎng)作為背景場(chǎng),包含了周期振蕩平穩(wěn)的晴天天氣成分;晴天天氣大氣電場(chǎng)能量集中于長(zhǎng)周期振蕩分量,而雷暴電場(chǎng)能量主要是集中于短周期振蕩分量。發(fā)生雷暴前,IMF(本征模態(tài)函數(shù))1分量的中心頻率會(huì)出現(xiàn)明顯跳躍或其對(duì)應(yīng)幅度明顯增大的現(xiàn)象。利用這些特征對(duì)隨機(jī)選出的38次過(guò)程進(jìn)行預(yù)報(bào)效果檢驗(yàn),得到預(yù)警的探測(cè)概率為842%。

    Abstract:

    An analysis of the near surface atmospheric electric field data in the summer of 2009 is presented based on the empirical mode decomposition (EMD) method. The vari scaled components of the atmospheric electric field in thunderstorm and fair weather are decomposed and the atmospheric electric field oscillation characteristics of two types of weather conditions are extracted and compared. The results show that the EMD method is suitable for the analysis of atmospheric electric field data. The atmospheric electric field in thunderstorm weather is under the background of atmospheric electric field in fair weather, and so contains the steady periodic oscillation compositions of fair weather. The atmospheric electric field energy in fair weather is concentrated in the long period oscillation component, while that in thunderstorm weather is mainly concentrated in the short period oscillation component. Before cloud to ground lightning occurring, the central frequency of IMF1 (IMF: Intrinsic Mode Function) will jump or the corresponding amplitude of IMF1 will increased significantly. According to these characteristics, 38 thunderstorms selected randomly are tested with lightning location data and the results show that the detection probability of warning is 842%.

    參考文獻(xiàn)
    相似文獻(xiàn)
    引證文獻(xiàn)
引用本文

徐棟璞,王振會(huì),曾慶鋒,敖雪.近地面大氣電場(chǎng)數(shù)據(jù)EMD方法分析[J].氣象科技,2013,41(1):170~176

復(fù)制
分享
文章指標(biāo)
  • 點(diǎn)擊次數(shù):
  • 下載次數(shù):
  • HTML閱讀次數(shù):
  • 引用次數(shù):
歷史
  • 收稿日期:2011-10-04
  • 定稿日期:2012-07-12
  • 錄用日期:
  • 在線發(fā)布日期: 2013-02-01
  • 出版日期:
您是第位訪問(wèn)者
技術(shù)支持:北京勤云科技發(fā)展有限公司
平遥县| 中宁县| 佛冈县| 海盐县| 林甸县| 定兴县| 新宾| 荣成市| 高清| 瓦房店市| 彰化县| 中阳县| 孝昌县| 中超| 江津市| 永定县| 赤峰市| 临安市| 扬州市| 嘉善县| 鄂托克前旗| 伊通| 台中市| 都江堰市| 高清| 天峻县| 思南县| 全南县| 怀宁县| 镇江市| 宝山区| 民和| 张家界市| 海宁市| 雷山县| 天祝| 敖汉旗| 松溪县| 惠水县| 宣威市| 同德县|